Evaporative cooling — pad and water sizing.

Compute pad face area, indicative water flow and expected ΔT from tunnel-fan cfm and outside conditions.

Inputs

Results

Pad face area
220.2 m²

Design face velocity 1.5 m/s for 6-inch pads.

Pad efficiency
75%

Saturation efficiency assumption — confirm against the pad manufacturer's data.

Inlet air ΔT
10.5 °C

Inlet 27.5 °C. Wet-bulb temperature is the physical floor; cooling can never go below it.

Humidity suitability
Evaporative cooling viable

Wet-bulb depression 14.0 °C. Confirm against local design-day humidity data, not annual averages.

Water flow
661 L/min

3 L/min per m² of pad face while pads run.

Related equipment categories

Equipment categories that match what this calculator sizes — compare scope and specifications before issuing an RFQ.

In short

This cooling calculator is a free browser tool for commercial poultry projects. Enter your own figures and it returns a class-4 planning estimate (about ±30%) under conservative, expected and optimistic scenarios. Use it to size an investment and to brief manufacturers — a firm supplier quote always overrides the estimate.

How to use this calculator

  1. Enter your project figures. Replace the default values in the cooling calculator with your own flock size, targets and local costs. Defaults are commercial-sector averages, not a recommendation.
  2. Compare the three scenarios. Switch between conservative, expected and optimistic to see how sensitive the result is to your assumptions before committing capital.
  3. Read the assumptions. Check the assumptions panel so you know what the model excludes — typically taxes, import duties, special civil works and land.
  4. Turn the output into a quote request. Send the resulting figures in a single request to receive comparable offers from qualified third-party manufacturers.