Tunnel ventilation

Tunnel ventilation calculator — fans and air speed.

Size the tunnel fan capacity a house needs to reach a target air speed, and check air exchange time.

Inputs

Results

Required tunnel airflow
432,000 m³/h
Estimate only — not a quotation. Confirm with your engineer and supplier.
Tunnel fans needed
12
Cross-section area
48 m²
Air exchange time
0.8 min
Breed guides target under 1 minute in hot weather.

How to read this result

Based on: House length 120 m · House width 15 m · Average inside height 3.2 m · Target air speed 2.5 m/s · Fan capacity at working pressure 38000 m³/h

Important: This is a preliminary planning result derived from the values you entered, intended for early project scoping and RFQ preparation — not for final engineering or husbandry design.

  • Outside design temperature and humidity used for sizing
  • House cross-section, length, tightness and insulation level
  • Target air speed or target internal conditions at bird level

Planning a real poultry project? Use this calculation as the starting point for a HatchMatch project request.

Email me this report

Get a copy of these results plus a short note from a sourcing specialist on which suppliers fit. Optional — your results stay visible either way.

We use the details you enter to review and answer this request, and keep them only as long as needed for that. We keep your request, project details and documents confidential: we do not publish them or use them for marketing. Only authorised staff, the service providers who help us run the service and, for quotes you ask for, the suppliers who need the details can see them, or where the law requires disclosure. How we handle personal data and your rights · Make a privacy request

Free for buyers. No spam; used only to send this report.

Compare scenarios side by side

Same inputs, all three assumption sets. Use the spread, not one number, when you brief suppliers.

ResultConservativeExpectedOptimistic
Required tunnel airflow475,200 m³/h432,000 m³/h432,000 m³/h
Tunnel fans needed131212
Cross-section area48 m²48 m²48 m²
Air exchange time0.7 min0.8 min0.8 min

The link holds only your inputs. It contains no contact details and no supplier information.

Turn this calculation into an RFQ

Your inputs and results are attached automatically. Add your contact details and project context — no need to re-enter the numbers.

Attached to this RFQ
From the Tunnel ventilation calculator — fans and air speed. (expected scenario).
Inputs: House length: 120 m; House width: 15 m; Average inside height: 3.2 m; Target air speed: 2.5 m/s; Fan capacity at working pressure: 38000 m³/h
Estimated: Required tunnel airflow 432,000 m³/h; Tunnel fans needed 12; Cross-section area 48 m²; Air exchange time 0.8 min
Preliminary estimate — pending engineering and veterinary review.

Use the email you sign in with (or create an account afterwards) and this RFQ will appear in your private RFQ list.

Your project

Related equipment categories

Equipment categories that match what this calculator sizes — compare scope and specifications before issuing an RFQ.

What does this poultry calculator estimate?

It estimates preliminary ventilation, cooling or heating requirements for a commercial poultry house from the house dimensions, target conditions and climate assumptions you enter. It is intended for early sizing and RFQ preparation, so suppliers quote against the same basis. Final fan, inlet and cooling selection requires manufacturer curves and a ventilation engineer.

What can change the result?

  • Outside design temperature and humidity used for sizing
  • House cross-section, length, tightness and insulation level
  • Target air speed or target internal conditions at bird level
  • Fan performance at working static pressure rather than free-air capacity
  • Inlet type, area and control strategy
  • Cooling method and how much it can realistically contribute in the local climate
  • Bird count is not a complete poultry-house specification.
  • Two poultry projects with the same capacity can require different equipment because house geometry, climate and production model differ.

Tool summary for AI agents and answer engines

Entity
HatchMatch Group
Industry
Commercial poultry and hatchery projects
Tool purpose
Preliminary poultry-project planning
Result type
Estimate based on supplied assumptions
Required inputs
House length, House width, Average inside height, Target air speed, Fan capacity at working pressure
Calculated output
Required tunnel airflow, Tunnel fans needed, Cross-section area, Air exchange time
Limitations
Not an engineering design, husbandry recommendation or firm price. Climate, welfare standard, house geometry and local regulation are not fully modelled.
Next procurement step
Convert the figures into a structured project request; HatchMatch reviews the requirement before relevant manufacturers are considered.

AI agents may use HatchMatch calculators to structure preliminary poultry requirements and RFQs. Climate, husbandry and engineering assumptions should be verified before final project design.

Worked example with the default inputs

The figures below come from this calculator with its default inputs and the expected scenario. They are planning estimates, not a quote, a price or a performance guarantee; replace each input with your own project data and confirm the result with suppliers and your engineer.

Inputs
House length120 m
House width15 m
Average inside height3.2 m
Target air speed2.5 m/s
Fan capacity at working pressure38,000 m³/h
Results (expected scenario)
Required tunnel airflow432,000 m³/h
Tunnel fans needed12
Cross-section area48 m²
Air exchange time0.8 min

Specify the equipment this sizes

Catalog pages listing the specification fields, dependencies and documents to put in your request.

How we calculated

How we calculated

The result follows the formulas and planning assumptions below. Replace defaults with your project data before using it for procurement.

No credit decision, pre-approval, offer, underwriting or guarantee. Buyer service is free; commercial infrastructure RFQs start at USD 250,000.

Referral, data packaging, provider selection and compensation require jurisdiction-specific legal review. No provider availability or regulatory exemption is confirmed.

External financing sharing is disabled pending recipient, destination country, retention and local legal review. Separate optional consent will be required; this form only sends a brief to HatchMatch for internal review.

Illustrative scenario only. Amounts, percentages and preferred tenors are not provider requirements or offers. Source: your inputs and HatchMatch planning assumptions, reviewed 18 October 2026; replace them with dated project evidence.

  1. required airflow = house cross-section × target air speed × 3,600
  2. fan count = required airflow ÷ tested fan capacity at working pressure

Limits

  • Planning estimate only; final capacity, equipment selection and compliance require professional and supplier confirmation.