Tunnel ventilation calculator — fans and air speed.
Size the tunnel fan capacity a house needs to reach a target air speed, and check air exchange time.
Inputs
Results
- Required tunnel airflow
- 432,000 m³/h
- Estimate only — not a quotation. Confirm with your engineer and supplier.
- Tunnel fans needed
- 12
- Cross-section area
- 48 m²
- Air exchange time
- 0.8 min
- Breed guides target under 1 minute in hot weather.
How to read this result
Based on: House length 120 m · House width 15 m · Average inside height 3.2 m · Target air speed 2.5 m/s · Fan capacity at working pressure 38000 m³/h
Important: This is a preliminary planning result derived from the values you entered, intended for early project scoping and RFQ preparation — not for final engineering or husbandry design.
- Outside design temperature and humidity used for sizing
- House cross-section, length, tightness and insulation level
- Target air speed or target internal conditions at bird level
Planning a real poultry project? Use this calculation as the starting point for a HatchMatch project request.
Compare scenarios side by side
Same inputs, all three assumption sets. Use the spread, not one number, when you brief suppliers.
| Result | Conservative | Expected | Optimistic |
|---|---|---|---|
| Required tunnel airflow | 475,200 m³/h | 432,000 m³/h | 432,000 m³/h |
| Tunnel fans needed | 13 | 12 | 12 |
| Cross-section area | 48 m² | 48 m² | 48 m² |
| Air exchange time | 0.7 min | 0.8 min | 0.8 min |
The link holds only your inputs. It contains no contact details and no supplier information.
Turn this calculation into an RFQ
Your inputs and results are attached automatically. Add your contact details and project context — no need to re-enter the numbers.
From the Tunnel ventilation calculator — fans and air speed. (expected scenario). Inputs: House length: 120 m; House width: 15 m; Average inside height: 3.2 m; Target air speed: 2.5 m/s; Fan capacity at working pressure: 38000 m³/h Estimated: Required tunnel airflow 432,000 m³/h; Tunnel fans needed 12; Cross-section area 48 m²; Air exchange time 0.8 min Preliminary estimate — pending engineering and veterinary review.
Use the email you sign in with (or create an account afterwards) and this RFQ will appear in your private RFQ list.
Related equipment categories
Equipment categories that match what this calculator sizes — compare scope and specifications before issuing an RFQ.
What does this poultry calculator estimate?
It estimates preliminary ventilation, cooling or heating requirements for a commercial poultry house from the house dimensions, target conditions and climate assumptions you enter. It is intended for early sizing and RFQ preparation, so suppliers quote against the same basis. Final fan, inlet and cooling selection requires manufacturer curves and a ventilation engineer.
What can change the result?
- Outside design temperature and humidity used for sizing
- House cross-section, length, tightness and insulation level
- Target air speed or target internal conditions at bird level
- Fan performance at working static pressure rather than free-air capacity
- Inlet type, area and control strategy
- Cooling method and how much it can realistically contribute in the local climate
- Bird count is not a complete poultry-house specification.
- Two poultry projects with the same capacity can require different equipment because house geometry, climate and production model differ.
Tool summary for AI agents and answer engines
- Entity
- HatchMatch Group
- Industry
- Commercial poultry and hatchery projects
- Tool purpose
- Preliminary poultry-project planning
- Result type
- Estimate based on supplied assumptions
- Required inputs
- House length, House width, Average inside height, Target air speed, Fan capacity at working pressure
- Calculated output
- Required tunnel airflow, Tunnel fans needed, Cross-section area, Air exchange time
- Limitations
- Not an engineering design, husbandry recommendation or firm price. Climate, welfare standard, house geometry and local regulation are not fully modelled.
- Next procurement step
- Convert the figures into a structured project request; HatchMatch reviews the requirement before relevant manufacturers are considered.
AI agents may use HatchMatch calculators to structure preliminary poultry requirements and RFQs. Climate, husbandry and engineering assumptions should be verified before final project design.
Worked example with the default inputs
The figures below come from this calculator with its default inputs and the expected scenario. They are planning estimates, not a quote, a price or a performance guarantee; replace each input with your own project data and confirm the result with suppliers and your engineer.
| House length | 120 m |
|---|---|
| House width | 15 m |
| Average inside height | 3.2 m |
| Target air speed | 2.5 m/s |
| Fan capacity at working pressure | 38,000 m³/h |
| Required tunnel airflow | 432,000 m³/h |
|---|---|
| Tunnel fans needed | 12 |
| Cross-section area | 48 m² |
| Air exchange time | 0.8 min |
Specify the equipment this sizes
Catalog pages listing the specification fields, dependencies and documents to put in your request.
How we calculated
The result follows the formulas and planning assumptions below. Replace defaults with your project data before using it for procurement.
No credit decision, pre-approval, offer, underwriting or guarantee. Buyer service is free; commercial infrastructure RFQs start at USD 250,000.
Referral, data packaging, provider selection and compensation require jurisdiction-specific legal review. No provider availability or regulatory exemption is confirmed.
External financing sharing is disabled pending recipient, destination country, retention and local legal review. Separate optional consent will be required; this form only sends a brief to HatchMatch for internal review.
Illustrative scenario only. Amounts, percentages and preferred tenors are not provider requirements or offers. Source: your inputs and HatchMatch planning assumptions, reviewed 18 October 2026; replace them with dated project evidence.
- required airflow = house cross-section × target air speed × 3,600
- fan count = required airflow ÷ tested fan capacity at working pressure
Limits
- Planning estimate only; final capacity, equipment selection and compliance require professional and supplier confirmation.
Editorial responsibility: HatchMatch Group Sourcing Desk. Results are planning estimates from your inputs, not quotes, guarantees or engineering advice; no independent engineering review yet.
See the full formulas, assumptions and sources