Calculator guide

Ventilation calculator: full guide

This guide explains what the ventilation calculator computes, how each input changes the result, and how to turn the output into a comparable request for quotation. Worked examples below are produced with the same engine that powers the live tool.

Open the calculator

How to use this calculator

  1. 1

    Enter your project figures

    Replace the default values in the ventilation calculator with your own flock size, targets and local costs. Defaults are commercial-sector averages, not a recommendation.

  2. 2

    Compare the three scenarios

    Switch between conservative, expected and optimistic to see how sensitive the result is to your assumptions before committing capital.

  3. 3

    Read the assumptions

    Check the assumptions panel so you know what the model excludes — typically taxes, import duties, special civil works and land.

  4. 4

    Turn the output into a quote request

    Send the resulting figures in a single request to receive comparable offers from qualified third-party manufacturers.

Every input explained

Default values are commercial-sector averages. Replace them with your own figures — your data always overrides the defaults.

House width (m)
14
Sidewall height (m)
2.6
Target air speed (m/s)
2.0 m/s temperate; 2.5-3.0 hot climates. — 2.5

Worked examples

Three realistic cases, computed live with the calculator engine.

Baseline case

Reference values under the expected scenario — a good starting point for a first project.

Inputs

  • House width14 m
  • Sidewall height2.6 m
  • Target air speed2.5 m/s

Results

  • Cross-section36.4 m²
  • Tunnel airflow91.0 m³/s
  • Peak airflow required192,818 cfm
  • 48-inch fans (at working pressure)10

Scale-up case

The same project with flock size increased 2.5×, to show how the result scales.

Inputs

  • House width24 m
  • Sidewall height2.6 m
  • Target air speed2.5 m/s

Results

  • Cross-section62.4 m²
  • Tunnel airflow156.0 m³/s
  • Peak airflow required330,545 cfm
  • 48-inch fans (at working pressure)16

Conservative case

Reference values under the conservative scenario, with a safety margin on performance.

Inputs

  • House width14 m
  • Sidewall height2.6 m
  • Target air speed2.5 m/s

Results

  • Cross-section36.4 m²
  • Tunnel airflow91.0 m³/s
  • Peak airflow required221,741 cfm
  • 48-inch fans (at working pressure)11

Planning assumptions

  • The ventilation calculator uses common commercial-sector parameters; your own measured data always overrides the defaults.
  • The conservative scenario adds a safety margin; the optimistic scenario assumes favourable operating conditions.
  • Taxes, import duties, special civil works and land cost are excluded unless stated otherwise.

Frequently asked questions