Heating calculator: full guide

This guide explains what the heating calculator computes, how each input changes the result, and how to turn the output into a comparable request for quotation. Worked examples below are produced with the same engine that powers the live tool.

Open the calculator

How to use this calculator

  1. 1

    Enter your project figures

    Defaults are illustrative model inputs, not verified industry averages. Replace them with your records, dated quotes and professionally reviewed assumptions.

  2. 2

    Compare the three scenarios

    Switch between conservative, expected and optimistic to see how sensitive the result is to your assumptions before committing capital.

  3. 3

    Read the assumptions

    Check the assumptions panel so you know what the model excludes — typically taxes, import duties, special civil works and land.

  4. 4

    Turn the output into a quote request

    Put the figures into one written project request. Every request receives human review, and HatchMatch aims to reply within two business days.

Every input explained

Defaults are illustrative model inputs, not verified industry averages. Replace them with your records, dated quotes and professionally reviewed assumptions.

Floor area (m²)
1,800
Inside-outside ΔT (°C)
Brooding target ~32°C; design outside minimum sets ΔT. — 25
Envelope U-value (W/m²·K)
0.35 well-insulated; 0.6 baseline; >0.8 poor. — 0.5
Minimum ventilation (m³/h per m²)
Brooding minimum ventilation for CO2 and moisture control. — 1.2
Brooder capacity (BTU/hr)
40,000
Burner efficiency (%)
90
Equivalent full-load hours (h/day)
Peak-equivalent running hours during brooding. — 10
LPG price (USD/kg)
0.9

Worked examples

Three illustrative model scenarios, computed with the calculator engine; not observed farms or promised outcomes.

Baseline case

Illustrative defaults under the expected scenario, not a recommended design or verified farm.

Inputs

  • Floor area1,800 m²
  • Inside-outside ΔT25 °C
  • Envelope U-value0.5 W/m²·K
  • Minimum ventilation1.2 m³/h per m²
  • Brooder capacity40,000 BTU/hr
  • Burner efficiency90 %
  • Equivalent full-load hours10 h/day
  • LPG price0.9 USD/kg

Results

  • Envelope loss22.5 kW
  • Ventilation loss17.8 kW
  • Total heat load40.3 kW
  • Peak BTU/hr137572

Scale-up case

Selected capacity-related inputs increased by up to 2.5× within field limits; check every input shown.

Inputs

  • Floor area1,800 m²
  • Inside-outside ΔT25 °C
  • Envelope U-value0.5 W/m²·K
  • Minimum ventilation1.2 m³/h per m²
  • Brooder capacity100,000 BTU/hr
  • Burner efficiency90 %
  • Equivalent full-load hours10 h/day
  • LPG price0.9 USD/kg

Results

  • Envelope loss22.5 kW
  • Ventilation loss17.8 kW
  • Total heat load40.3 kW
  • Peak BTU/hr137572

Conservative case

The same inputs under the engine’s conservative scenario; not a statistical confidence interval.

Inputs

  • Floor area1,800 m²
  • Inside-outside ΔT25 °C
  • Envelope U-value0.5 W/m²·K
  • Minimum ventilation1.2 m³/h per m²
  • Brooder capacity40,000 BTU/hr
  • Burner efficiency90 %
  • Equivalent full-load hours10 h/day
  • LPG price0.9 USD/kg

Results

  • Envelope loss22.5 kW
  • Ventilation loss17.8 kW
  • Total heat load48.4 kW
  • Peak BTU/hr165086

Planning assumptions

  • The heating calculator uses illustrative model inputs unless its methodology identifies a source; replace them with measured records and reviewed assumptions.
  • Scenario labels describe model assumptions, not probabilities, verified improvements or guaranteed safety margins.
  • Taxes, import duties, special civil works and land cost are excluded unless stated otherwise.