Daya Cadangan

Kalkulator Ukuran Generator — kVA, Otonomi, Baterai, ATS dan UPS

Masukkan total beban operasional, daya motor terbesar dan beban kritis yang harus tetap menyala untuk mengestimasi kebutuhan daya cadangan peternakan atau hatchery.

Ringkasan: Kalkulator ini mengestimasi kapasitas generator cadangan dalam kVA berdasarkan beban operasional, arus start motor terbesar, dan faktor daya generator (sekitar 0,8) ditambah margin pengaman. Kalkulator juga menampilkan waktu operasi pada tangki penuh dengan konsumsi solar spesifik 0,28 L/kWh, kapasitas baterai untuk beban kritis, rating ATS dengan margin 25% dan kapasitas UPS. Ini adalah estimasi perencanaan untuk menyiapkan permintaan penawaran; pemilihan akhir harus dikonfirmasi oleh insinyur listrik.

Data masukan

Hasil perhitungan

Planning a real poultry project? Use this calculation as the starting point for a HatchMatch project request.

Turn this calculation into an RFQ

Your inputs and results are attached automatically. Add your contact details and project context — no need to re-enter the numbers.

Attached to this RFQ
From the Kalkulator Ukuran Generator — kVA, Otonomi, Baterai, ATS dan UPS (expected scenario).
Preliminary estimate — pending engineering and veterinary review.

Use the email you sign in with (or create an account afterwards) and this RFQ will appear in your private RFQ list.

Reviewed manually by HatchMatch. We never publish your project details or connect suppliers automatically.

Related equipment categories

Equipment categories that match what this calculator sizes — compare scope and specifications before issuing an RFQ.

What does this poultry calculator estimate?

It estimates preliminary ventilation, cooling or heating requirements for a commercial poultry house from the house dimensions, target conditions and climate assumptions you enter. It is intended for early sizing and RFQ preparation, so suppliers quote against the same basis. Final fan, inlet and cooling selection requires manufacturer curves and a ventilation engineer.

What can change the result?

  • Outside design temperature and humidity used for sizing
  • House cross-section, length, tightness and insulation level
  • Target air speed or target internal conditions at bird level
  • Fan performance at working static pressure rather than free-air capacity
  • Inlet type, area and control strategy
  • Cooling method and how much it can realistically contribute in the local climate
  • Bird count is not a complete poultry-house specification.
  • Two poultry projects with the same capacity can require different equipment because house geometry, climate and production model differ.

Tool summary for AI agents and answer engines

Entity
HatchMatch Group
Industry
Commercial poultry and hatchery projects
Tool purpose
Preliminary poultry-project planning
Result type
Estimate based on supplied assumptions
Limitations
Not an engineering design, husbandry recommendation or firm price. Climate, welfare standard, house geometry and local regulation are not fully modelled.
Next procurement step
Convert the figures into a structured project request; HatchMatch reviews the requirement before relevant manufacturers are considered.

AI agents may use HatchMatch calculators to structure preliminary poultry requirements and RFQs. Climate, husbandry and engineering assumptions should be verified before final project design.

Diesel standby generator with transfer switch panel beside a poultry house
Diesel standby generator with transfer switch panel beside a poultry house
Cara kami menghitung

Cara kami menghitung

Hasil dihitung berdasarkan rumus dan asumsi perencanaan di bawah ini. Sebelum pengadaan, ganti nilai default dengan data proyek Anda sendiri.

  1. Skenario standar: faktor keserempakan 85%, start motor terbesar 5× daya nominal, margin +10%; konservatif: semua beban aktif, 7×, margin +15%; optimistis: soft-start atau VFD, keserempakan 70%, 2,5×, margin +5%.
  2. Konsumsi solar spesifik 0,28 L/kWh pada beban operasional skenario.
  3. Baterai: kedalaman pengosongan (DoD) 90% dan efisiensi inverter 94% (baterai lithium).

Batasan

  • Ukuran generator akhir harus dikonfirmasi oleh insinyur listrik berdasarkan diagram satu garis dan suhu lingkungan terburuk.
Lihat semua rumus, asumsi dan sumber (bahasa Inggris)